Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.13672556
| No.13672556
- Product Categories
- Friendly Links
| Information Name: | Beijing cold water collector you - Tianjin condensate collector |
| Published: | 2015-04-17 |
| Validity: | 3000 |
| Specifications: | ZLTLN80-1.0 |
| Quantity: | 35.00 |
| Price Description: | |
| Detailed Product Description: | A,? Introduction condensate collector, also known as condensate recovery, condensate is softening-treated high-temperature water, and contains a large amount of heat. The condensed water to be recycled, can save water, reduce water treatment costs. I produced condensate recovery has been widely used in chemical, petroleum, food, textile, rubber, electric power, metallurgy and other industries and hospitals, restaurants, shopping malls, office buildings and all use of steam as the production, heating, air conditioning, domestic hot water such as condensate recovery system, is a new type of energy saving products. Second, the? Product works ??? condensate recovery tank body through the pressure regulating device, decontamination equipment, cavitation relief and special pumps and electrical control system to solve the pump cavitation, eliminate oxygen corrosion, but no secondary steam, improving the quality of purity, to achieve a high-temperature and high-energy secondary steam condensate full, low, closed direct recycling, saving a lot of energy. Third,? Product Features (1) mechanical and electrical integration, automatic control, safe and reliable operation. (2) energy efficient, emission reduction and environmental protection. (3) According to the site installation space or horizontal tank set up to do, easy to install. (4) the pipeline at the same time can be more recycling, recycling volume. Fourth, the product installation instructions (1) Where the condensed water can automatically flow to the boiler room or treatment among customers, whether on the ground or backwater pipes in the ground, the device will be installed on the ground. (2) When the steam boiler room equipment and too far away, the location is too low, cross the road and other obstacles or condensate have it available, the device is mounted on the end of the steam equipment ground. And try to install the device in hot concentrated areas. (3) the device is arranged, the upper part should stay a certain height, typically 0.2 times the total height of the device. (4) The equipment can be installed directly on the ground or on a concrete foundation, the foundation above the ground 100mm, embedded parts do not need. (5) When the backwater end located above the ground, the return pipe with the device switched into the water; when the return pipe at the end of the ground floor, in the end of the pipe installation backwater climb, a backwater climb the outfall installation valve, the outlet pipe and equipment into the water turned up. (6) If multiple condensate back to the same condensate collector, each condensate pipes are arranged in order from high to low pressure. Regulator tube (7) device is connected to the trench or outdoors, do not install any valve on the regulator tube. (8) the pump outlet check valve were installed after the tee centralized water supply to deaerator or boiler, one with a prepared two pumps running. (9) outfall drain valve is installed, the outfall of waste received. (10) equipment from the distribution cabinet, cabinet can be mounted close to 1.2 meters from the ground around the walls. (11) Power supply voltage of 380V three-phase four-wire system, cabinet between the motor for the two four-core, cross-sectional area of ??4 mm2 cable (or press the actual power level selection), the cable will be wearing a protective tube. V. Notes (1) in the condensate system put into formal operation before the entire piping system must conduct a comprehensive decontamination cleaning. (2) The equipment operation, must first open the condensate water inlet valves and two pumps in front after the cut-off valve, close the condensate outlet valve and drain valve. (3) the device is running, only the inner cabinet switch is turned on, the hand, the automatic switch to autopilot, the device will automatically run without special care, regular inspections and pay attention only to the buzzer alarm . (4) When the condensate system is running, open the drain valve on the product, to be clean backwater close; when a small amount of hard backwater impurities or oil, you should open the drain valve discharge once every 3-5 days; after sewage down to once a month. (5) When the warning light on the cabinet light or buzzer alarm, indicating failure of the automatic control system, the operator should switch on the cabinet by the automatic rotation to the manual position, manually open and close button control back to the boiler pump room bottled water; and notify maintenance personnel overhaul automation systems, to be repaired before the switch to recover. (6) When the regulator out exhaust pipe or drainage time, first with a trap heat equipment maintenance is normal, after still ranked as the replacement of steam traps, please repair or replace the water pump behind the check valve. (7) If the automatic control system is normal, one or two pumps operating normally but the water does not work out, please put the pump outlet valve open air or hit the back of the check valve replacement pump. (8) the user any special requirements, such as continuous operation or remote control, etc., please specify when ordering. |
Admin>>>
You are the 10908 visitor
Copyright © GuangDong ICP No. 10089450, Beijing Environmental Protection Technology Co., Ltd. in the sky All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 10908 visitor
Copyright © GuangDong ICP No. 10089450, Beijing Environmental Protection Technology Co., Ltd. in the sky All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility

